| Device model | AC60 -11005 |
AC60 -11010 |
AC60 -11030 |
AC60 -11050 |
AC60 -11100 |
AC60 -11150 |
AC60 -11200 |
AC60 -11300 |
| Rated power | 0.5kVA | 1kVA | 3kVA | 5kVA | 10kVA | 15kVA | 20kVA | 30kVA |
| Input AC indicators | ||||||||
| Power supply system | Single phase two wire+PE | |||||||
| Voltage range | 220V ( ±15%) | |||||||
| Frequency range | 50/60Hz ( ±10%) | |||||||
| Characteristics of output AC | ||||||||
| Power supply system | Single phase two wire | |||||||
| Voltage range | Low:0~150VL -N ,HIgh:0~300VL -N | |||||||
| Current range(Low) | 4A | 9A | 27A | 45A | 90A | 136A | 181A | 272A |
| Current range(HIgh) | 2A | 4A | 13A | 22A | 45A | 68A | 90A | 136A |
| Frequency range | Fixed frequency:50/60Hz ,frequency modulation:45~65Hz | |||||||
| Source effect | ≤0.1%F.S | |||||||
| Load effect | ≤0.1%F.S | |||||||
| Voltage accuracy | ≤0.1%F.S | |||||||
| Frequency accuracy | ≤0.01%F.S | |||||||
| Voltage harmonics | ≤2% | |||||||
| Response time | ≤5ms | |||||||
| Equipment efficiency | ≥90% | |||||||
| Overload capacity | 120%~150% ,1min;150%~200% ,2s; ≥200% ,immediately turn off the output | |||||||
| System function | ||||||||
| Oline adjustment function | Adjustable output voltage and frequency online | |||||||
| Quick setting function | Customizable settings for multiple sets of output voltage and frequency | |||||||
| Memory function | After power failure recovery, the last output mode and parameters can be remembered | |||||||
| Protection function | Input overvoltage and undervoltage, phase loss protection, output overvoltage, overcurrent, overload, short circuit protection, internal overheating protection, etc | |||||||
| Display and Communication | ||||||||
| Local operation | Digital LED | LCD display screen | ||||||
| Display resolution | Voltage:0.1V , Current:0.1A ,Frequency:0.1Hz ,Power:0.1kW | |||||||
| Display accuracy | Voltage:0.1%F.S , Current:0.2%F.S ,Frequency:0.01% ,Power:0.3%F.S | |||||||
| Remote communication | No communication | RS 485/LAN | ||||||
| Communication Protocol | No communication protocol | standard Modbus RTU/Modbus TCPIP | ||||||
| Safety | ||||||||
| Pressure Resistance Strength | 2000Vdc/60s/no breakdown | |||||||
| Insulation Resistance | ≥20MΩ@500Vdc | |||||||
| Grounding Resistance | ≤100mΩ | |||||||
| Noise | ≤65dB(A) | |||||||
| Usage environment | ||||||||
| Work Environment | It can work continuously for 24 hours when the ambient temperature is -20 ºC~45 ºC and the relative humidity is 0~95% | |||||||
| Cooling Method | Fan forced air cooling | |||||||
| Protection Level | IP 21 | |||||||
| Altitude | ≤5000m@>2000m derating use | |||||||
| Size(W*D*H)mm | 440*460*133 (Including footings) |
440*460*133 (Including footings) |
440*460*242 (Including footings) |
350*560*675 (Including moving wheels) |
400*660*800 (Including moving wheels) |
400*660*800 (Including moving wheels) |
500*820*1100 (Including moving wheels) |
500*820*1100 (Including moving wheels) |
| Device model | AC60 -31100 |
AC60 -31150 |
AC60 -31200 |
AC60 -31300 |
AC60 -31450 |
AC60 -31600 |
AC60 -311000 |
| Rated power | 10kVA | 15kVA | 20kVA | 30kVA | 45kVA | 60kVA | 100kVA |
| Input AC indicators | |||||||
| Power supply system | Three-phase four-wire+PE | ||||||
| Voltage range | 380V ( ±15%) | ||||||
| Frequency range | 50/60Hz ( ±10%) | ||||||
| Characteristics of output AC | |||||||
| Power supply system | Single phase two wire | ||||||
| Voltage range | Low:0~150VL -N ,HIgh:0~300VL -N | ||||||
| Current range(Low) | 90A | 136A | 181A | 272A | 409A | 545A | 909A |
| Current range(HIgh) | 45A | 68A | 90A | 136A | 204A | 272A | 454A |
| Frequency range | Fixed frequency:50/60Hz ,frequency modulation:45~65Hz | ||||||
| Source effect | ≤0.1%F.S | ||||||
| Load effect | ≤0.1%F.S | ||||||
| Voltage accuracy | ≤0.1%F.S | ||||||
| Frequency accuracy | ≤0.01%F.S | ||||||
| Voltage harmonics | ≤2% | ||||||
| Response time | ≤5ms | ||||||
| Equipment efficiency | ≥90% | ||||||
| Overload capacity | 120%~150% ,1min;150%~200% ,2s; ≥200% ,immediately turn off the output | ||||||
| System function | |||||||
| Oline adjustment function | Adjustable output voltage and frequency online | ||||||
| Quick setting function | Customizable settings for multiple sets of output voltage and frequency | ||||||
| Memory function | After power failure recovery, the last output mode and parameters can be remembered | ||||||
| Protection function | Input overvoltage and undervoltage, phase loss protection, output overvoltage, overcurrent, overload, short circuit protection, internal overheating protection, etc | ||||||
| Display and Communication | |||||||
| Local operation | Digital LED | LCD display screen | |||||
| Display resolution | Voltage:0.1V , Current:0.1A ,Frequency:0.1Hz ,Power:0.1kW | ||||||
| Display accuracy | Voltage:0.1%F.S , Current:0.2%F.S ,Frequency:0.01% ,Power:0.3%F.S | ||||||
| Remote communication |
RS 485/LAN | ||||||
| Communication Protocol | standard Modbus RTU/Modbus TCPIP | ||||||
| Safety | |||||||
| Pressure Resistance Strength | 2000Vdc/60s/no breakdown | ||||||
| Insulation Resistance | ≥20MΩ@500Vdc | ||||||
| Grounding Resistance | ≤100mΩ | ||||||
| Noise | ≤65dB(A) | ||||||
| Usage environment | |||||||
| Work Environment | It can work continuously for 24 hours when the ambient temperature is -20 ºC~45 ºC and the relative humidity is 0~95% | ||||||
| Cooling Method | Fan forced air cooling | ||||||
| Protection Level | IP 21 | ||||||
| Altitude | ≤5000m@>2000m derating use | ||||||
| Size(W*D*H)mm | 400*650*800 (Including moving wheels) |
400*650*800 (Including moving wheels) |
500*820*1105 (Including moving wheels) |
500*820*1105 (Including moving wheels) |
520*1160*1355 (Including moving wheels) |
520*1160*1355 (Including moving wheels) |
520*1160*1355 (Including moving wheels) |
| Device model | AC60 -33100 |
AC60 -33200 |
AC60 -33300 |
AC60 -33450 |
AC60 -33600 |
AC60 -33900 |
AC60 -331000 |
AC60 -331200 |
AC60 -331500 |
|
| Rated power | 10kVA | 20kVA | 30kVA | 45kVA | 60kVA | 90kVA | 100kVA | 120kVA | 150kVA | |
| Input AC indicators | ||||||||||
| Power supply system | Three phase four wire+PE | |||||||||
| Voltage range | 380V ( ±15%) | |||||||||
| Frequency range | 50/60Hz ( ±10%) | |||||||||
| Characteristics of output AC | ||||||||||
| Power supply system | Three phase four wire | |||||||||
| Voltage range | Low:0~150VL -N ,HIgh:0~300VL -N | |||||||||
| Current range(Low) | 30A | 60A | 90A | 136A | 181A | 272A | 303A | 363A | 454A | |
| Current range(HIgh) | 15A | 30A | 45A | 68A | 90A | 136A | 151A | 181A | 227A | |
| Frequency range | Fixed frequency:50/60Hz ,frequency modulation:45~65Hz | |||||||||
| Source effect | ≤0.1%F.S | |||||||||
| Load effect | ≤0.1%F.S | |||||||||
| Voltage accuracy | ≤0.1%F.S | |||||||||
| Frequency accuracy | ≤0.01%F.S | |||||||||
| Voltage harmonics | ≤2% | |||||||||
| Response time | ≤5ms | |||||||||
| Equipment efficiency | ≥90% | |||||||||
| Overload capacity | 120%~150% ,1min;150%~200% ,2s; ≥200% ,immediately turn off the output | |||||||||
| System function | ||||||||||
| Oline adjustment function | Adjustable output voltage and frequency online | |||||||||
| Quick setting function | Customizable settings for multiple sets of output voltage and frequency | |||||||||
| Memory function | After power failure recovery, the last output mode and parameters can be remembered | |||||||||
| Protection function | Input overvoltage and undervoltage, phase loss protection, output overvoltage, overcurrent, overload, short circuit protection, internal overheating protection, etc | |||||||||
| Display and Communication | ||||||||||
| Local operation | LCD display screen | |||||||||
| Display resolution | Voltage:0.1V ,Current:0.1A ,Frequency:0.1Hz ,Power:0.1kW | |||||||||
| Display accuracy | Voltage:0.1%F.S ,Current:0.2%F.S ,Frequency:0.01% ,Power:0.3%F.S | |||||||||
| Remote communication | RS 485/LAN | |||||||||
| Communication Protocol | standard Modbus RTU/Modbus TCPIP | |||||||||
| Safety | ||||||||||
| Pressure Resistance Strength | 2000Vdc/60s/no breakdown | |||||||||
| Insulation Resistance | ≥20MΩ@500Vdc | |||||||||
| Grounding Resistance | ≤100mΩ | |||||||||
| Noise | ≤65dB(A) | |||||||||
| Usage environment | ||||||||||
| Work Environment | It can work continuously for 24 hours when the ambient temperature is -20 ºC~45 ºC and the relative humidity is 0~95% | |||||||||
| Cooling Method | Fan forced air cooling | |||||||||
| Protection Level | IP 21 | |||||||||
| Altitude | ≤5000m@>2000m derating use | |||||||||
| Size(W*D*H)mm | 500*820*1105 (Including moving wheels) |
500*820*1105 (Including moving wheels) |
520*1160*1355 (Including moving wheels) |
520*1160*1355 (Including moving wheels) |
650*1420*1470 (Including moving wheels) |
650*1420*1470 (Including moving wheels) |
650*1420*1470 (Including moving wheels) |
650*1420*1470 (Including moving wheels) |
650*1420*1470 (Including moving wheels) |
|
| Device model | AC60 -332000 |
AC60 -333000 |
AC60 -334000 |
AC60 -336000 |
AC60 -338000 |
AC60 -3310000 |
AC60 -3312000 |
AC60 -3316000 |
AC60 -3320000 |
| Rated power | 200kVA | 300kVA | 400kVA | 600kVA | 800kVA | 1000kVA | 1200kVA | 1600kVA | 2000kVA |
| Input AC indicators | |||||||||
| Power supply system | Three phase four wire+PE | ||||||||
| Voltage range | 380V ( ±15%) | ||||||||
| Frequency range | 50/60Hz ( ±10%) | ||||||||
| Characteristics of output AC | |||||||||
| Power supply system | Three phase four wire+PE | ||||||||
| Voltage range | Low:0~150VL -N ,HIgh:0~300VL -N | ||||||||
| Current range(Low) | 303A | 454A | 606A | 911A | 1215A | 1519A | 1823A | 2431A | 3038A |
| Frequency range | Fixed frequency:50/60Hz ,frequency modulation:45~65Hz | ||||||||
| Source effect | ≤0.1%F.S | ||||||||
| Load effect | ≤0.1%F.S | ||||||||
| Voltage accuracy | ≤0.1%F.S | ||||||||
| Frequency accuracy | ≤0.01%F.S | ||||||||
| Voltage harmonics | ≤2% | ||||||||
| Response time | ≤5ms | ||||||||
| Equipment efficiency | ≥90% | ||||||||
| Overload capacity | 120%~150% ,1min;150%~200% ,2s; ≥200% ,immediately turn off the output | ||||||||
| System function | |||||||||
| Oline adjustment function | Adjustable output voltage and frequency online | ||||||||
| Quick setting function | Customizable settings for multiple sets of output voltage and frequency | ||||||||
| Memory function | After power failure recovery, the last output mode and parameters can be remembered | ||||||||
| Protection function | Input overvoltage and undervoltage, phase loss protection, output overvoltage, overcurrent, overload, short circuit protection, internal overheating protection, etc | ||||||||
| Display and Communication | |||||||||
| Local operation | LCD display screen | ||||||||
| Display resolution | Voltage:0.1V , Current:0.1A ,Frequency:0.1Hz ,Power:0.1kW | ||||||||
| Display accuracy | Voltage:0.1%F.S , Current:0.2%F.S ,Frequency:0.01% ,Power:0.3%F.S | ||||||||
| Remote communication | RS 485/LAN | ||||||||
| Communication Protocol | standard Modbus RTU/Modbus TCPIP | ||||||||
| Safety | |||||||||
| Pressure Resistance Strength | 2000Vdc/60s/no breakdown | ||||||||
| Insulation Resistance | ≥20MΩ@500Vdc | ||||||||
| Grounding Resistance | ≤100mΩ | ||||||||
| Noise | ≤65dB(A) | ||||||||
| Usage environment | |||||||||
| Work Environment | It can work continuously for 24 hours when the ambient temperature is -20 ºC~45 ºC and the relative humidity is 0~95% | ||||||||
| Cooling Method | Fan forced air cooling | ||||||||
| Protection Level | IP 21 | ||||||||
| Altitude | ≤5000m@>2000m derating use | ||||||||
| Size(W*D*H)mm | 1550*850*1985 (Including moving wheels) |
1550*850*1985 (Including moving wheels) |
1910*1160 *1940 | 3100*900 *2080 | 3100*900 *2080 | 4900*1600 *2080 | 4900*1600 *2080 | 4900*1600 *2080 | 4900*1600 *2080 |