Customization: | Available |
---|---|
Output Frequency: | 45-67/100/120/200/240Hz |
Number of Phases: | Single/Three |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Device model | AC60 -334000 |
AC60 -336300 |
AC60 -338000 |
AC60 -3310000 |
AC60 -3312500 |
AC60 -3316000 |
AC60 -3325000 |
AC60 -3350000 |
Rated power | 400kVA | 630kVA | 800kVA | 1000kVA | 1250kVA | 1600kVA | 2500kVA | 5000kVA |
Input AC indicators | ||||||||
Power supply system | Three phase four wire+PE | |||||||
Voltage range | 380V ( ±15%) | |||||||
Frequency range | 50/60Hz ( ±10%) | |||||||
Characteristics of output AC | ||||||||
Power supply system | Three phase four wire | |||||||
Voltage range | 0~460VL-L | |||||||
Current range | 524A | 826A | 1049A | 1312A | 1640A | 2100A | 3280A | 6560A |
Frequency range | Fixed frequency:50/60Hz ,frequency modulation:45~65Hz | |||||||
Source effect | ≤0.1%F.S | |||||||
Load effect | ≤0.1%F.S | |||||||
Voltage accuracy | ≤0.1%F.S | |||||||
Frequency accuracy | ≤0.01%F.S | |||||||
Voltage harmonics | ≤2% | |||||||
Response time | ≤5ms | |||||||
Equipment efficiency | ≥90% | |||||||
Overload capacity | 120%~150% ,1min;150%~200% ,2s; ≥200% ,immediately turn off the output | |||||||
System function | ||||||||
Oline adjustment function | Adjustable output voltage and frequency online | |||||||
Memory function | After power failure recovery, the last output mode and parameters can be remembered | |||||||
Protection function | Input overvoltage and undervoltage, phase loss protection, output overvoltage, overcurrent, overload, short circuit protection, internal overheating protection, etc | |||||||
Display and Communication | ||||||||
Local operation | LCD display screen | |||||||
Display resolution | Voltage:0.1V ,Current:0.1A ,Frequency:0.1Hz ,Power:0.1kW | |||||||
Display accuracy | Voltage:0.1%F.S ,Current:0.2%F.S ,Frequency:0.01% ,Power:0.3%F.S | |||||||
Remote communication | RS 485/LAN | |||||||
Communication Protocol | standard Modbus RTU/Modbus TCPIP | |||||||
Safety | ||||||||
Pressure Resistance Strength | 2000Vdc/60s/no breakdown | |||||||
Insulation Resistance | ≥20MΩ@500Vdc | |||||||
Grounding Resistance | ≤100mΩ | |||||||
Noise | ≤65dB(A) | |||||||
Usage environment | ||||||||
Work Environment | It can work continuously for 24 hours when the ambient temperature is -20 ºC~45 ºC and the relative humidity is 0~95% | |||||||
Cooling Method | Fan forced air cooling, air conditioning auxiliary heat dissipation (optional) | |||||||
Protection Level | Power IP 21, Container IP 54 (optional) | |||||||
Altitude | ≤5000m@>2000m derating use | |||||||
Power supply(w*d*h)mm | 1910*1160 *1940 | 3100*900 *2080 | 3100*900 *2080 | 3100*900 *2080 | 4900*1600 *2080 | 4900*1600 *2080 | 4900*1600 *2080 | 7000*1600 *2080 |
Container(w*d*h)mm | 3500*2400 *2900 | 4500*2400 *2900 | 4500*2400 *2900 | 4500*2400 *2900 | 7500*2400 *2900 | 7500*2400 *2900 | 7500*2400 *2900 | 12000*2400 *2900 |
Device model | GYBP60 -3312500 |
GYBP60 -3316000 |
GYBP60 -3320000 |
GYBP60 -3330000 |
GYBP60 -3350000 |
GYBP60 -3380000 |
GYBP60 -33100000 |
Rated power | 1250kVA | 1600kVA | 2000kVA | 3000kVA | 5000kVA | 8000kVA | 10000kVA |
Input AC indicators | |||||||
Power supply system | Three phase four wire+PE | ||||||
Voltage range | 3~10kV ( ±10%) | ||||||
Frequency range | 50/60Hz ( ±10%) | ||||||
Characteristics of output AC | |||||||
Power supply system | Three phase four wire | ||||||
Voltage range | 0.4kV/0.44kV/6.0kV/6.6kV | ||||||
Current range | 120A | 153A | 192A | 288A | 480A | 768A | 960A |
Frequency range | Fixed frequency:50/60Hz ,frequency modulation:45~65Hz | ||||||
Source effect | ≤1%F.S | ||||||
Load effect | ≤1%F.S | ||||||
Voltage accuracy | ≤0.1%F.S | ||||||
Frequency accuracy | ≤0.1%F.S | ||||||
Voltage harmonics | ≤3% | ||||||
Response time | ≤20ms | ||||||
Equipment efficiency | ≥90% | ||||||
Overload capacity | 120%~150% ,1min;150%~200% ,2s; ≥200% ,immediately turn off the output | ||||||
System function | |||||||
Oline adjustment function | Adjustable output voltage and frequency online | ||||||
Memory function | After power failure recovery, the last output mode and parameters can be remembered | ||||||
Protection function | Input overvoltage and undervoltage, phase loss protection, output overvoltage, overcurrent, overload, short circuit protection, internal overheating protection, etc | ||||||
Display and Communication | |||||||
Local operation | LCD display screen | ||||||
Display resolution | Voltage:0.1V ,Current:0.1A ,Frequency:0.1Hz ,Power:0.1kW | ||||||
Display accuracy | Voltage:0.1%F.S ,Current:0.2%F.S ,Frequency:0.01% ,Power:0.3%F.S | ||||||
Remote communication | RS 485/LAN | ||||||
Communication Protocol | standard Modbus RTU/Modbus TCPIP | ||||||
Safety | |||||||
Pressure Resistance Strength | 2000Vdc/60s/no breakdown | ||||||
Insulation Resistance | ≥20MΩ@500Vdc | ||||||
Grounding Resistance | ≤100mΩ | ||||||
Noise | ≤65dB(A) | ||||||
Usage environment | |||||||
Work Environment | It can work continuously for 24 hours when the ambient temperature is -20 ºC~45 ºC and the relative humidity is 0~95% | ||||||
Cooling Method | Fan forced air cooling, air conditioning auxiliary heat dissipation (optional) | ||||||
Protection Level | Power IP 21, Container IP 54 (optional) | ||||||
Altitude | ≤5000m@>2000m derating use |
600kVA Shore Power Supply in China 1800kVA Shore Power Supply in ZheJiang
1250kVA Shore Power Supply in ShanDong 1000kVA Shore Power Supply in China
300kVA Shore Power Supply in HaiNan 1000kVA Shore Power Supply in QuanZhou
1.Q:Are you manufacturers?