Customization: | Available |
---|---|
Output Frequency: | 45-67/100/120/200/240Hz |
Number of Phases: | Single/Three |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Device model | AC60 -11005 |
AC60 -11010 |
AC60 -11030 |
AC60 -11050 |
AC60 -11100 |
AC60 -11150 |
AC60 -11200 |
AC60 -11300 |
Rated power | 0.5kVA | 1kVA | 3kVA | 5kVA | 10kVA | 15kVA | 20kVA | 30kVA |
Input AC indicators | ||||||||
Power supply system | Single phase two wire+PE | |||||||
Voltage range | 220V ( ±15%) | |||||||
Frequency range | 50/60Hz ( ±10%) | |||||||
Characteristics of output AC | ||||||||
Power supply system | Single phase two wire | |||||||
Voltage range | Low:0~150VL -N ,HIgh:0~300VL -N | |||||||
Current range(Low) | 4A | 9A | 27A | 45A | 90A | 136A | 181A | 272A |
Current range(HIgh) | 2A | 4A | 13A | 22A | 45A | 68A | 90A | 136A |
Frequency range | Fixed frequency:50/60Hz ,frequency modulation:45~65Hz | |||||||
Source effect | ≤0.1%F.S | |||||||
Load effect | ≤0.1%F.S | |||||||
Voltage accuracy | ≤0.1%F.S | |||||||
Frequency accuracy | ≤0.01%F.S | |||||||
Voltage harmonics | ≤2% | |||||||
Response time | ≤5ms | |||||||
Equipment efficiency | ≥90% | |||||||
Overload capacity | 120%~150% ,1min;150%~200% ,2s; ≥200% ,immediately turn off the output | |||||||
System function | ||||||||
Oline adjustment function | Adjustable output voltage and frequency online | |||||||
Quick setting function | Customizable settings for multiple sets of output voltage and frequency | |||||||
Memory function | After power failure recovery, the last output mode and parameters can be remembered | |||||||
Protection function | Input overvoltage and undervoltage, phase loss protection, output overvoltage, overcurrent, overload, short circuit protection, internal overheating protection, etc | |||||||
Display and Communication | ||||||||
Local operation | Digital LED | LCD display screen | ||||||
Display resolution | Voltage:0.1V , Current:0.1A ,Frequency:0.1Hz ,Power:0.1kW | |||||||
Display accuracy | Voltage:0.1%F.S , Current:0.2%F.S ,Frequency:0.01% ,Power:0.3%F.S | |||||||
Remote communication | No communication | RS 485/LAN | ||||||
Communication Protocol | No communication protocol | standard Modbus RTU/Modbus TCPIP | ||||||
Safety | ||||||||
Pressure Resistance Strength | 2000Vdc/60s/no breakdown | |||||||
Insulation Resistance | ≥20MΩ@500Vdc | |||||||
Grounding Resistance | ≤100mΩ | |||||||
Noise | ≤65dB(A) | |||||||
Usage environment | ||||||||
Work Environment | It can work continuously for 24 hours when the ambient temperature is -20 ºC~45 ºC and the relative humidity is 0~95% | |||||||
Cooling Method | Fan forced air cooling | |||||||
Protection Level | IP 21 | |||||||
Altitude | ≤5000m@>2000m derating use | |||||||
Size(W*D*H)mm | 440*460*133 (Including footings) |
440*460*133 (Including footings) |
440*460*242 (Including footings) |
350*560*675 (Including moving wheels) |
400*660*800 (Including moving wheels) |
400*660*800 (Including moving wheels) |
500*820*1100 (Including moving wheels) |
500*820*1100 (Including moving wheels) |
Device model | AC60 -31100 |
AC60 -31150 |
AC60 -31200 |
AC60 -31300 |
AC60 -31450 |
AC60 -31600 |
AC60 -311000 |
Rated power | 10kVA | 15kVA | 20kVA | 30kVA | 45kVA | 60kVA | 100kVA |
Input AC indicators | |||||||
Power supply system | Three-phase four-wire+PE | ||||||
Voltage range | 380V ( ±15%) | ||||||
Frequency range | 50/60Hz ( ±10%) | ||||||
Characteristics of output AC | |||||||
Power supply system | Single phase two wire | ||||||
Voltage range | Low:0~150VL -N ,HIgh:0~300VL -N | ||||||
Current range(Low) | 90A | 136A | 181A | 272A | 409A | 545A | 909A |
Current range(HIgh) | 45A | 68A | 90A | 136A | 204A | 272A | 454A |
Frequency range | Fixed frequency:50/60Hz ,frequency modulation:45~65Hz | ||||||
Source effect | ≤0.1%F.S | ||||||
Load effect | ≤0.1%F.S | ||||||
Voltage accuracy | ≤0.1%F.S | ||||||
Frequency accuracy | ≤0.01%F.S | ||||||
Voltage harmonics | ≤2% | ||||||
Response time | ≤5ms | ||||||
Equipment efficiency | ≥90% | ||||||
Overload capacity | 120%~150% ,1min;150%~200% ,2s; ≥200% ,immediately turn off the output | ||||||
System function | |||||||
Oline adjustment function | Adjustable output voltage and frequency online | ||||||
Quick setting function | Customizable settings for multiple sets of output voltage and frequency | ||||||
Memory function | After power failure recovery, the last output mode and parameters can be remembered | ||||||
Protection function | Input overvoltage and undervoltage, phase loss protection, output overvoltage, overcurrent, overload, short circuit protection, internal overheating protection, etc | ||||||
Display and Communication | |||||||
Local operation | Digital LED | LCD display screen | |||||
Display resolution | Voltage:0.1V , Current:0.1A ,Frequency:0.1Hz ,Power:0.1kW | ||||||
Display accuracy | Voltage:0.1%F.S , Current:0.2%F.S ,Frequency:0.01% ,Power:0.3%F.S | ||||||
Remote communication |
RS 485/LAN | ||||||
Communication Protocol | standard Modbus RTU/Modbus TCPIP | ||||||
Safety | |||||||
Pressure Resistance Strength | 2000Vdc/60s/no breakdown | ||||||
Insulation Resistance | ≥20MΩ@500Vdc | ||||||
Grounding Resistance | ≤100mΩ | ||||||
Noise | ≤65dB(A) | ||||||
Usage environment | |||||||
Work Environment | It can work continuously for 24 hours when the ambient temperature is -20 ºC~45 ºC and the relative humidity is 0~95% | ||||||
Cooling Method | Fan forced air cooling | ||||||
Protection Level | IP 21 | ||||||
Altitude | ≤5000m@>2000m derating use | ||||||
Size(W*D*H)mm | 400*650*800 (Including moving wheels) |
400*650*800 (Including moving wheels) |
500*820*1105 (Including moving wheels) |
500*820*1105 (Including moving wheels) |
520*1160*1355 (Including moving wheels) |
520*1160*1355 (Including moving wheels) |
520*1160*1355 (Including moving wheels) |
Device model | AC60 -33100 |
AC60 -33200 |
AC60 -33300 |
AC60 -33450 |
AC60 -33600 |
AC60 -33900 |
AC60 -331000 |
AC60 -331200 |
AC60 -331500 |
|
Rated power | 10kVA | 20kVA | 30kVA | 45kVA | 60kVA | 90kVA | 100kVA | 120kVA | 150kVA | |
Input AC indicators | ||||||||||
Power supply system | Three phase four wire+PE | |||||||||
Voltage range | 380V ( ±15%) | |||||||||
Frequency range | 50/60Hz ( ±10%) | |||||||||
Characteristics of output AC | ||||||||||
Power supply system | Three phase four wire | |||||||||
Voltage range | Low:0~150VL -N ,HIgh:0~300VL -N | |||||||||
Current range(Low) | 30A | 60A | 90A | 136A | 181A | 272A | 303A | 363A | 454A | |
Current range(HIgh) | 15A | 30A | 45A | 68A | 90A | 136A | 151A | 181A | 227A | |
Frequency range | Fixed frequency:50/60Hz ,frequency modulation:45~65Hz | |||||||||
Source effect | ≤0.1%F.S | |||||||||
Load effect | ≤0.1%F.S | |||||||||
Voltage accuracy | ≤0.1%F.S | |||||||||
Frequency accuracy | ≤0.01%F.S | |||||||||
Voltage harmonics | ≤2% | |||||||||
Response time | ≤5ms | |||||||||
Equipment efficiency | ≥90% | |||||||||
Overload capacity | 120%~150% ,1min;150%~200% ,2s; ≥200% ,immediately turn off the output | |||||||||
System function | ||||||||||
Oline adjustment function | Adjustable output voltage and frequency online | |||||||||
Quick setting function | Customizable settings for multiple sets of output voltage and frequency | |||||||||
Memory function | After power failure recovery, the last output mode and parameters can be remembered | |||||||||
Protection function | Input overvoltage and undervoltage, phase loss protection, output overvoltage, overcurrent, overload, short circuit protection, internal overheating protection, etc | |||||||||
Display and Communication | ||||||||||
Local operation | LCD display screen | |||||||||
Display resolution | Voltage:0.1V ,Current:0.1A ,Frequency:0.1Hz ,Power:0.1kW | |||||||||
Display accuracy | Voltage:0.1%F.S ,Current:0.2%F.S ,Frequency:0.01% ,Power:0.3%F.S | |||||||||
Remote communication | RS 485/LAN | |||||||||
Communication Protocol | standard Modbus RTU/Modbus TCPIP | |||||||||
Safety | ||||||||||
Pressure Resistance Strength | 2000Vdc/60s/no breakdown | |||||||||
Insulation Resistance | ≥20MΩ@500Vdc | |||||||||
Grounding Resistance | ≤100mΩ | |||||||||
Noise | ≤65dB(A) | |||||||||
Usage environment | ||||||||||
Work Environment | It can work continuously for 24 hours when the ambient temperature is -20 ºC~45 ºC and the relative humidity is 0~95% | |||||||||
Cooling Method | Fan forced air cooling | |||||||||
Protection Level | IP 21 | |||||||||
Altitude | ≤5000m@>2000m derating use | |||||||||
Size(W*D*H)mm | 500*820*1105 (Including moving wheels) |
500*820*1105 (Including moving wheels) |
520*1160*1355 (Including moving wheels) |
520*1160*1355 (Including moving wheels) |
650*1420*1470 (Including moving wheels) |
650*1420*1470 (Including moving wheels) |
650*1420*1470 (Including moving wheels) |
650*1420*1470 (Including moving wheels) |
650*1420*1470 (Including moving wheels) |
Device model | AC60 -332000 |
AC60 -333000 |
AC60 -334000 |
AC60 -336000 |
AC60 -338000 |
AC60 -3310000 |
AC60 -3312000 |
AC60 -3316000 |
AC60 -3320000 |
Rated power | 200kVA | 300kVA | 400kVA | 600kVA | 800kVA | 1000kVA | 1200kVA | 1600kVA | 2000kVA |
Input AC indicators | |||||||||
Power supply system | Three phase four wire+PE | ||||||||
Voltage range | 380V ( ±15%) | ||||||||
Frequency range | 50/60Hz ( ±10%) | ||||||||
Characteristics of output AC | |||||||||
Power supply system | Three phase four wire+PE | ||||||||
Voltage range | Low:0~150VL -N ,HIgh:0~300VL -N | ||||||||
Current range(Low) | 303A | 454A | 606A | 911A | 1215A | 1519A | 1823A | 2431A | 3038A |
Frequency range | Fixed frequency:50/60Hz ,frequency modulation:45~65Hz | ||||||||
Source effect | ≤0.1%F.S | ||||||||
Load effect | ≤0.1%F.S | ||||||||
Voltage accuracy | ≤0.1%F.S | ||||||||
Frequency accuracy | ≤0.01%F.S | ||||||||
Voltage harmonics | ≤2% | ||||||||
Response time | ≤5ms | ||||||||
Equipment efficiency | ≥90% | ||||||||
Overload capacity | 120%~150% ,1min;150%~200% ,2s; ≥200% ,immediately turn off the output | ||||||||
System function | |||||||||
Oline adjustment function | Adjustable output voltage and frequency online | ||||||||
Quick setting function | Customizable settings for multiple sets of output voltage and frequency | ||||||||
Memory function | After power failure recovery, the last output mode and parameters can be remembered | ||||||||
Protection function | Input overvoltage and undervoltage, phase loss protection, output overvoltage, overcurrent, overload, short circuit protection, internal overheating protection, etc | ||||||||
Display and Communication | |||||||||
Local operation | LCD display screen | ||||||||
Display resolution | Voltage:0.1V , Current:0.1A ,Frequency:0.1Hz ,Power:0.1kW | ||||||||
Display accuracy | Voltage:0.1%F.S , Current:0.2%F.S ,Frequency:0.01% ,Power:0.3%F.S | ||||||||
Remote communication | RS 485/LAN | ||||||||
Communication Protocol | standard Modbus RTU/Modbus TCPIP | ||||||||
Safety | |||||||||
Pressure Resistance Strength | 2000Vdc/60s/no breakdown | ||||||||
Insulation Resistance | ≥20MΩ@500Vdc | ||||||||
Grounding Resistance | ≤100mΩ | ||||||||
Noise | ≤65dB(A) | ||||||||
Usage environment | |||||||||
Work Environment | It can work continuously for 24 hours when the ambient temperature is -20 ºC~45 ºC and the relative humidity is 0~95% | ||||||||
Cooling Method | Fan forced air cooling | ||||||||
Protection Level | IP 21 | ||||||||
Altitude | ≤5000m@>2000m derating use | ||||||||
Size(W*D*H)mm | 1550*850*1985 (Including moving wheels) |
1550*850*1985 (Including moving wheels) |
1910*1160 *1940 | 3100*900 *2080 | 3100*900 *2080 | 4900*1600 *2080 | 4900*1600 *2080 | 4900*1600 *2080 | 4900*1600 *2080 |
1.Q:Are you manufacturers?