| Output Type: | Single |
|---|---|
| Warranty: | 1 Year |
| Output Power: | 20kw-600kw |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency





Model | BDM20 -1000/50-50-1 | BDM40 -1000/50-100-1 | BDM80 -1000/50-200-1 | BDM160 -1000/50-400-1 | BDM320 -1000/50-800-1 | BDM400 -1000/50-800-1 | BDM500 -1000/50-1250-1 | BDM600 -1000/50-1200-1 |
Rated Power | 20kW | 40kW | 80kW | 160kW | 320kW | 400kW | 500kW | 600kW |
Rated Current | 50A | 100A | 200A | 400A | 800A | 1000A | 1000A | 1200A |
Rated Voltage | 400V | 400V | 400V | 400V | 400V | 400V | 500V | 500V |
Voltage Range | 50~1000V (Standard) /100~2000V (Optional) | |||||||
AC Input Specifications | ||||||||
Power Configuration | Three-phase four-wire+PE | |||||||
Voltage Range | 400V(±15%) | |||||||
Frequency Range | 50Hz(±10%) | |||||||
Power Factor | ≥0.99 | |||||||
Current Harmonics | THDi≤ 3% | |||||||
DC Output Electrical Characteristics | ||||||||
Channels | Single Channel / Dual Channel (Optional) | |||||||
Peak Power | 1.2Pe(60s) | |||||||
Peak Current | 1.2Ie(60s) | |||||||
Line Regulation | ≤ 0.1%F.S | |||||||
Load Regulation | ≤ 0.1%F.S | |||||||
Voltage Accuracy | ≤ 0.1%F.S | |||||||
Current Accuracy | ≤ 0.1%F.S | |||||||
Voltage Ripple | ≤ 0.2%F.S | |||||||
Response Time | ≤ 3ms (10%~90% Step Load) | |||||||
Switching Time | ≤ 6ms (-90%~+90% Switching) | |||||||
Efficiency | ≥94% | |||||||
Energy Regeneration Performance | ||||||||
Grid Voltage Range | 360~440V | |||||||
Grid Frequency Range | 47~53Hz | |||||||
Power Factor | ≥0.99 | |||||||
Current Harmonics | THDi≤5% | |||||||
Regenerative Power | Supports Full-Range Power Regeneration | |||||||
System Functions | ||||||||
Operating Mode | Constant Voltage / Constant Current / Constant Power | |||||||
Isolation Method | High-Frequency Isolation Transformer | |||||||
Remote Compensation | Adaptive Compensation for Line Voltage Drop | |||||||
Protection Functions | Overvoltage, Undervoltage, Phase Loss, Overcurrent, Short Circuit, Overload, Overtemperature, Emergency Stop, etc. | |||||||
Display & Communication | ||||||||
Local Operation | LCD Display | |||||||
Remote Communication | RS 485/LAN/CAN | |||||||
Communication Protocol | Standard ModbusRTU/Modbus TCPIP/CAN2.0 | |||||||
Safety Performance | ||||||||
Dielectric Withstand | 2000Vdc/60s/ No Breakdown | |||||||
Insulation Resistance | ≥ 20MΩ(500Vdc) | |||||||
Ground Resistance | ≤100mΩ | |||||||
Noise | ≤65dB(A) | |||||||
Operating Environment | ||||||||
Operating Conditions | Ambient Temperature-20℃ ~45℃, Relative Humidity 0~95%; Continuous 24-Hour Operation | |||||||
Cooling Method | Forced-Air Fan Cooling | |||||||
Protection Rating | IP20 | |||||||
Altitude | ≤ 5000m @ > 2000m Derating Required | |||||||
Dimensions (W*D*H) mm | 482*700*133 | 482*700*222 | 650*750*1200 | 650*750*1800 | 1400*800*1960 | |||
Remark: Please contact our sales staff if additional models or customized solutions are required. | ||||||||