| Application: | High-performance Transducer, Three Phase Transducer, Single-phase Transducer, High Frequency Converter Transducer |
|---|---|
| Output Type: | Triple |
| Principle of Work: | PLC Control |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Device model | AC50 -11100 |
AC50 -31300 |
AC50 -33450 |
AC50 -331000 |
AC50 -332000 |
AC50 -334000 |
AC50 -338000 |
| Rated power | 10kVA | 30kVA | 45kVA | 100kVA | 200kVA | 400kVA | 800kVA |
| Input AC indicators | |||||||
| Power supply system | Single phase two wire+PE | Three phase four wire+PE | Three phase four wire+PE | ||||
| Voltage range | 176~264VL-N | ||||||
| Frequency range | 30~100Hz | ||||||
| Characteristics of output AC | |||||||
| Power supply system | Single phase two wire | Single phase two wire | Three phase four wire | ||||
| Voltage range | 220VL-N | ||||||
| Current range | 45A | 136A | 68A | 151A | 303A | 606A | 1215A |
| Frequency range | Fixed frequency:50/60Hz | ||||||
| Source effect | ≤0.1%F.S | ||||||
| Load effect | ≤0.1%F.S | ||||||
| Voltage accuracy | ≤0.1%F.S | ||||||
| Frequency accuracy | ≤0.01%F.S | ||||||
| Voltage harmonics | ≤2% | ||||||
| Response time | ≤5ms | ||||||
| Equipment efficiency | ≥90% | ||||||
| Overload capacity | 120%~150% ,1min;150%~200% ,2s; ≥200% ,immediately turn off the output | ||||||
| System function | |||||||
| Oline adjustment function | Adjustable output voltage and frequency online | ||||||
| Memory function | After power failure recovery, the last output mode and parameters can be remembered | ||||||
| Protection function | Input overvoltage and undervoltage, phase loss protection, output overvoltage, overcurrent, overload, short circuit protection, internal overheating protection, etc | ||||||
| Display and Communication | |||||||
| Local operation | LCD display screen | ||||||
| Display resolution | Voltage:0.1V ,Current:0.1A ,Frequency:0.1Hz ,Power:0.1kW | ||||||
| Display accuracy | Voltage:0.1%F.S ,Current:0.2%F.S ,Frequency:0.01% ,Power:0.3%F.S | ||||||
| Remote communication | RS 485/LAN | ||||||
| Communication Protocol | standard Modbus RTU/Modbus TCPIP | ||||||
| Safety | |||||||
| Pressure Resistance Strength | 2000Vdc/60s/no breakdown | ||||||
| Insulation Resistance | ≥20MΩ@500Vdc | ||||||
| Grounding Resistance | ≤100mΩ | ||||||
| Noise | ≤65dB(A) | ||||||
| Usage environment | |||||||
| Work Environment | It can work continuously for 24 hours when the ambient temperature is -20 ºC~45 ºC and the relative humidity is 0~95% | ||||||
| Cooling Method | Fan forced air cooling | ||||||
| Protection Level | IP 21 | ||||||
| Altitude | ≤5000m@>2000m derating use | ||||||
| Size(W*D*H)mm | 400*660*800 (Including moving wheels) |
500*820*1105 (Including moving wheels) |
520*1160*1355 (Including moving wheels) |
650*1420*1470 (Including moving wheels) |
1550*850*1985 (Including moving wheels) |
1910*1160*1940 | 3100*900*2080 |