| Application: | High-performance Transducer, Three Phase Transducer, High Frequency Converter Transducer, High-performance Transducer, Three Phase Transducer, High Frequency Converter Transducer, High-performance Transducer, Three Phase Transducer, High Frequency Converter Transducer |
|---|---|
| Output Type: | Triple, Triple |
| Principle of Work: | AC DC AC + PWM/SPWM inverter control, AC DC AC + PWM/SPWM inverter control |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency











Model | AC60-11010 | AC60-11030 | AC60-11050 | AC60-11100 | AC60-11150 | AC60-11200 | AC60-11300 |
Rated Power | 1kVA | 3kVA | 5kVA | 10kVA | 15kVA | 20kVA | 30kVA |
Wiring System | Single-phase, 2-wire+PE | ||||||
Voltage Range | 220V(±15%) | ||||||
Frequency Range | 50/60Hz(±10%) | ||||||
Wiring System | Single-phase, 2-wire+PE | ||||||
Voltage Range | Low range: 0–150VL-N; high range: 0–300VL-N | ||||||
Current (Low) | 9A | 27A | 45A | 90A | 136A | 181A | 272A |
Current (High) | 4A | 13A | 22A | 45A | 68A | 90A | 136A |
Frequency Range | Fixed: 50/60Hz; adjustable: 45–65Hz | ||||||
Line Regulation | ≤ 0.1%F.S | ||||||
Load Regulation | ≤ 0.1%F.S | ||||||
Voltage Accuracy | ≤ 0.1%F.S | ||||||
Freq. Accuracy | ≤ 0.01%F.S | ||||||
Voltage THD | ≤2% | ||||||
Response Time | ≤5ms | ||||||
Efficiency | ≥90% | ||||||
Overload Capacity | 120%–150%: 1 min; 150%–200%: 2 s; ≥200%: immediate output shutdown | ||||||
Memory | Restores the last output mode and settings after power returns | ||||||
Protection | Output overvoltage, overcurrent, overload and short-circuit protection; internal overtemperature protection, etc. | ||||||
Local Control | DigitalLED | LCD Display | |||||
Display Resolution | Voltage: 0.1V; current: 0.1A; frequency: 0.1Hz; power: 0.1kW | ||||||
Display Accuracy | Voltage: 0.1% F.S.; current: 0.2% F.S.; frequency: 0.01%; power: 0.3% F.S. | ||||||
Remote Comms | None | RS 485/LAN | |||||
Comm. Protocol | None | StandardModbusRTU/Modbus TCPIP | |||||
Dielectric Test | 2000Vdc/60s/no breakdown | ||||||
Insulation Res. | ≥ 20MΩ@500Vdc | ||||||
Ground Res. | ≤100mΩ | ||||||
Noise | ≤65dB(A) | ||||||
Conditions | Ambient temperature–20°C to 45°C; RH: 0–95%; continuous 24/7 operation | ||||||
Cooling | Forced-air cooling | ||||||
Protection Rating | IP20 | ||||||
Altitude | ≤5000m; derating above 2000m | ||||||
W×D×H (mm) | 440*460*133(w/ feet) | 440*460*242(w/ feet) | 350*560*670(w/ casters) | 400*650*800(w/ casters) | 500*820*1100(w/ casters) | 520*1160*1360(w/ casters) | |
Reminder: The rated power of standard variable frequency power supply can be made from 1 to 2000 kVA. Please contact our sales staff if you need more models. We also support customization for special requirements. | |||||||