| Application: | High-performance Transducer, Three Phase Transducer, High Frequency Converter Transducer |
|---|---|
| Output Type: | Triple |
| Principle of Work: | PLC Control |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency




Model | HCT-31100 | HCT-31150 | HCT-31200 | HCT-31300 | HCT-31450 | HCT-311500 | HCT-315000 |
Rated Power | 10kVA | 15kVA | 20kVA | 30kVA | 45kVA | 150kVA | 500kVA |
AC Input Specifications | |||||||
Power Configuration | Three-phase, four-wire + PE | ||||||
Voltage Range | 380V(±15%) | ||||||
Frequency Range | 50/60Hz(±10%) | ||||||
AC Output Characteristics | |||||||
Power Configuration | Single-phase, two-wire + PE | ||||||
Voltage Range | 0~20VL-N | 0~30VL-N | 0~50VL-N/100VL-N | ||||
Current Range | 0-500A | 0-750A | 0-1000A | 0-1500A | 0-2250A | 0-5000A | 0~10000A/5000A |
Frequency Range | Fixed: 50/60 Hz; adjustable: 45–65 Hz | ||||||
Line Regulation | ≤ 0.1%F.S | ||||||
Load Regulation | ≤ 0.1%F.S | ||||||
Current Accuracy | ≤ 0.1%F.S | ||||||
Frequency Accuracy | ≤ 0.01%F.S | ||||||
Voltage Harmonic Distortion | ≤2% | ||||||
Response Time | ≤5ms | ||||||
Efficiency | ≥90% | ||||||
Overload Capacity | 120%–150% for 1 min; 150%–200% for 2 s; ≥ 200%: output shuts down immediately | ||||||
System Functions | |||||||
Memory Function | Retains the previous output mode and parameters after power is restored | ||||||
Protection Functions | Input overvoltage, undervoltage and phase-loss protection; output overvoltage, overcurrent, overload and short-circuit protection; internal overtemperature protection, etc. | ||||||
Display and Communication | |||||||
Local Operation | LCD Display | ||||||
Display Resolution | Voltage: 0.1 V; Current: 0.1 A; Frequency: 0.1 Hz; Power: 0.1 kW | ||||||
Display Accuracy | Voltage: 0.1% F.S.; Current: 0.2% F.S.; Frequency: 0.01%; Power: 0.3% F.S. | ||||||
Remote Communication | RS 485/LAN | ||||||
Communication Protocol | Standard Modbus RTU / Modbus TCP/IP | ||||||
Safety Performance | |||||||
Dielectric Strength | 2,000 VDC / 60 s / No breakdown | ||||||
Insulation Resistance | ≥ 20MΩ@500Vdc | ||||||
Grounding Resistance | ≤100mΩ | ||||||
Noise | ≤65dB(A) | ||||||
Operating Environment | |||||||
Operating Conditions | Continuous 24-hour operation at an ambient temperature of −20°C to 45°C and relative humidity of 0–95% | ||||||
Cooling Method | Forced-air cooling by fan | ||||||
Protection Rating | IP20 | ||||||
Altitude | ≤ 5,000 m; derating required above 2,000 m | ||||||
Dimensions (W × D × H), mm | 500 × 820 × 1100 (including casters) | 520 × 1160 × 1360 (including casters) | 1550 × 850 × 1985 (including casters) | 2700*1200*2080 | |||
Note: Contact sales for more models or customization. | |||||||